| description | Domain knowledge and workflows for pile load testing reports compliant with IS 2911 (Part 4) - 2013. Use when working on test calculations, report generation, PDF templates, pass/fail criteria, or adding new test types (IVPLT, RVPLT, Lateral, Uplift). This skill encodes Indian Standard formulas, acceptance criteria, report structure requirements, and chart specifications for pile foundation testing. |
PileTest Pro Domain Knowledge
This skill provides domain expertise for pile load testing and IS 2911-compliant report generation.
Quick Reference
Test Types & Load Multipliers
| Test Type | Code | Load Multiplier | Description |
|---|---|---|---|
| Initial Vertical | IVPLT |
2.5× design load | First test on new piles |
| Routine Vertical | RVPLT |
1.5× design load | Production/working piles |
| Lateral | LATERAL |
2.5× design load | Horizontal resistance |
| Uplift/Pullout | UPLIFT |
2.5× design load | Upward resistance |
Core Formulas
// Load from pressure (MT)
load = (pressureKgCm2 × ramAreaCm2) / 1000
// Average settlement (mm)
avgSettlement = (dg1 + dg2 + dg3 + dg4) / enabledGaugeCount
// Net settlement (mm)
netSettlement = maxSettlement - elasticRebound
// Safe load from 12mm criterion (MT)
safeLoad_12mm = (2/3) × loadAt12mmSettlement
// Safe load from ultimate criterion (MT)
safeLoad_ultimate = 0.5 × loadAt10PercentDiameter
Pass/Fail Criteria (IS 2911)
Vertical Tests (IVPLT/RVPLT):
- Net settlement ≤ 12mm (or 2% of pile diameter, whichever is less)
- Safe load = minimum of design load, safeLoad_12mm, safeLoad_ultimate
Workflow
1. Calculate Results
See references/is2911-standards.md for detailed calculation steps.
2. Generate Report
See references/report-structure.md for PDF section specifications.
3. Validate Readings
For IS 2911 compliance validation, see scripts/validate_readings.py.
Files
- references/is2911-standards.md - Complete IS 2911 Part 4 acceptance criteria
- references/report-structure.md - PDF report section specifications
- references/test-types.md - Detailed test type configurations
- scripts/validate_readings.py - Python validation for readings
- assets/templates/ - HTML report template patterns
Key Implementation Points
Settlement Calculations
- Max Settlement: Highest
avgSettlementMmduring LOADING phase - Elastic Rebound: Max settlement minus final settlement after full unload
- Net Settlement: Permanent settlement after load removal
Safe Load Determination
governingCriterion =
if (settlementLimit was reached) → "SETTLEMENT_12MM"
if (10% diameter was reached) → "ULTIMATE_10PCT_DIA"
else → "DESIGN_LOAD"
safeLoadAdopted = min(
designLoadT,
safeLoadFromSettlementT, // (2/3) × load at 12mm
safeLoadFromUltimateT // (1/2) × load at 10% dia
)