Claude Code Plugins

Community-maintained marketplace

Feedback

telecom-licensing-expert

@reggiechan74/vp-real-estate
1
0

Expert in telecommunications licensing agreements that grant telecom carriers (phone, internet, cable companies) access to install equipment in commercial buildings. Use when building owner is negotiating with telecom providers, reviewing carrier access rights, structuring equipment room licenses, analyzing riser and conduit rights, evaluating CRTC (Canadian Radio-television and Telecommunications Commission) compliance requirements, negotiating license fees and revenue sharing, or managing multiple competing carriers in one building. Key terms include telecommunications license, carrier access, equipment installation, riser rights, conduit rights, CRTC compliance, co-location, license vs lease, non-exclusive license, main distribution frame, telecom service provider

Install Skill

1Download skill
2Enable skills in Claude

Open claude.ai/settings/capabilities and find the "Skills" section

3Upload to Claude

Click "Upload skill" and select the downloaded ZIP file

Note: Please verify skill by going through its instructions before using it.

SKILL.md

name telecom-licensing-expert
description Expert in telecommunications licensing agreements that grant telecom carriers (phone, internet, cable companies) access to install equipment in commercial buildings. Use when building owner is negotiating with telecom providers, reviewing carrier access rights, structuring equipment room licenses, analyzing riser and conduit rights, evaluating CRTC (Canadian Radio-television and Telecommunications Commission) compliance requirements, negotiating license fees and revenue sharing, or managing multiple competing carriers in one building. Key terms include telecommunications license, carrier access, equipment installation, riser rights, conduit rights, CRTC compliance, co-location, license vs lease, non-exclusive license, main distribution frame, telecom service provider
tags commercial-real-estate, telecommunications, licensing-agreements, infrastructure-sharing, CRTC-compliance
capability Provides specialized expertise in telecommunications license agreements including carrier access rights, equipment installation, riser/conduit rights, CRTC regulatory compliance, co-location arrangements, and balancing building owner control with provider access needs
proactive true

You are an expert in telecommunications licensing agreements for commercial buildings.

What is a Telecom License?

Telecommunications License = Agreement granting telecom carrier (phone company, internet provider, cable company) right to install equipment in building and provide service to tenants.

Key distinction from lease: License is revocable permission to use space; lease is exclusive possessory right. Licenses are preferred for telecom to maintain building owner control.

Parties:

  • Licensor: Building owner/landlord
  • Licensee: Telecom carrier (Bell, Rogers, Telus, Shaw, Videotron, fiber providers, etc.)

Why Building Owners Grant Telecom Licenses

Benefits to building:

  • Attracts tenants (high-speed internet, phone service essential)
  • Increases building value (connectivity infrastructure)
  • Competitive advantage (multiple carrier options)
  • Potential revenue (license fees or revenue share)

Carrier's need:

  • Access to customer base (building tenants)
  • Physical infrastructure (equipment rooms, risers, rooftop antennas)
  • Rights of way through building

CRTC Regulatory Framework (Canada)

CRTC = Canadian Radio-television and Telecommunications Commission (federal regulator)

Key regulation: Telecommunications Act and CRTC policy require building owners to provide "reasonable access" to telecom carriers.

"Reasonable access" means:

  • Can't unreasonably deny carrier access to building
  • Must allow competing carriers (can't grant exclusive to one carrier)
  • Can charge "reasonable" fees (not excessive)
  • Can impose "reasonable" conditions (safety, insurance, location of equipment)

Building owner CAN:

  • Require license agreement
  • Designate specific equipment room and riser locations
  • Require insurance and indemnification
  • Charge reasonable license fees
  • Impose safety and operational requirements
  • Coordinate installation timing

Building owner CANNOT:

  • Grant exclusive license to one carrier (competition required)
  • Charge excessive fees that deny access
  • Unreasonably withhold consent
  • Require carrier to pay for building improvements unrelated to carrier's use

Key License Provisions

Grant of License

Non-exclusive license: Carrier has non-exclusive right to:

  • Install, operate, maintain, and repair telecom equipment in designated equipment room
  • Run cables through designated risers and conduits
  • Access rooftop for antennas (if applicable)
  • Provide telecom services to building tenants

Not a lease: No exclusive possession, revocable on notice, licensee is not "tenant"

Licensed Premises

Equipment Room:

  • Dedicated room or portion of room for carrier's equipment
  • Typically in basement or ground floor mechanical room
  • Size: 100-300 SF depending on building size
  • Power requirements: Dedicated electrical service
  • HVAC: 24/7 cooling for equipment
  • Security: Restricted access, only carrier's technicians

Risers:

  • Vertical pathways for cables through building (floor to floor)
  • Typically in building core, elevator shafts, or dedicated telecom shafts
  • Carrier's cables run alongside other utilities (hydro, plumbing, HVAC)

Conduits:

  • Horizontal pathways for cables on each floor
  • From riser to tenant demarcation point
  • May be shared with other carriers

Rooftop (if applicable):

  • Space for antennas, dishes, or wireless equipment
  • Defined area on roof plan
  • Carrier responsible for roof penetrations and waterproofing

Term

Typical: 5-10 years initial term with renewal options

Longer term (10-20 years): If carrier making substantial investment in equipment

Termination: Either party can terminate on 60-180 days' notice (varies)

Carrier's concern: Needs long enough term to recoup equipment investment

Building owner's concern: Flexibility if building sold, redeveloped, or carrier's equipment obsolete

License Fee

Three structures:

1. Flat annual fee: $2,000-$10,000/year per carrier depending on building size and market

  • Simple, predictable
  • No admin burden
  • Market rate varies by city and building class

2. Revenue share: Carrier pays percentage of revenue from building tenants (5-15%)

  • Aligns owner's revenue with carrier's success
  • Requires auditing carrier's revenue (complex)
  • Carrier resists (reveals customer info, admin burden)

3. No fee: Building owner provides space at no cost

  • Common for first carrier in building (increases building value)
  • Competition: Other carriers demand same terms

Market practice: Flat annual fee is most common for equipment room ($3K-$7K/year). Revenue share rare due to admin complexity.

Installation and Construction

Carrier's obligations:

  • Submit plans for equipment installation and cable routes to building owner for approval
  • Obtain building permits (if required)
  • Hire licensed contractors
  • Coordinate with building owner's property manager
  • Install equipment in workmanlike manner
  • Minimize disruption to tenants
  • Restore any damage from installation

Building owner's approval rights:

  • Location of equipment and cable routes
  • Timing of installation (to minimize tenant disruption)
  • Contractors and safety procedures
  • Compliance with building codes

Timing: Carrier wants rapid installation; building owner wants orderly process

Access and Security

Carrier's access:

  • 24/7 access to equipment room for maintenance and repairs
  • Reasonable notice to building owner (except emergencies)
  • Carrier's employees/contractors must sign in and be accompanied (or have building access card)

Security:

  • Equipment room locked, only carrier's technicians have key
  • Building owner's engineer has master key for emergencies
  • Carrier's equipment marked with carrier's name

Utilities

Electricity:

  • Carrier pays for dedicated electrical service to equipment room
  • Metered separately or estimated consumption
  • Carrier responsible for power costs

HVAC:

  • Carrier's equipment generates heat (requires cooling)
  • Building owner provides 24/7 HVAC to equipment room
  • Carrier pays proportionate share of HVAC costs (metered or estimated)

Typical arrangement: Carrier pays flat monthly utility fee (e.g., $200-$500/month) covering electricity and HVAC

Maintenance and Repairs

Carrier's responsibility:

  • Maintain carrier's equipment in good working order
  • Repair or replace malfunctioning equipment
  • Keep equipment room clean and organized
  • Remove obsolete equipment

Building owner's responsibility:

  • Maintain building structure, risers, equipment room shell
  • Provide HVAC and power to equipment room
  • Repair damage to building not caused by carrier

Coordination: If building repairs require carrier to relocate equipment, building owner must give advance notice (90-180 days) and provide alternative location at no cost to carrier

Alterations and Upgrades

Carrier's equipment upgrades: Carrier can upgrade equipment (new technology) with notice to building owner, subject to:

  • No material increase in space, power, or HVAC requirements
  • Approval of plans by building owner
  • Compliance with codes and standards

Building owner's alterations: If building owner renovates/redevelops building and needs carrier to relocate, building owner must:

  • Give 6-12 months' notice
  • Provide comparable alternative location at no cost
  • Pay carrier's reasonable relocation costs

Insurance and Indemnification

Carrier's insurance:

  • Commercial General Liability: $5M per occurrence
  • Property insurance for carrier's equipment
  • Building owner named as additional insured
  • Certificate of insurance provided annually

Indemnification:

  • Carrier indemnifies building owner for claims arising from carrier's equipment, installation, or operations
  • Building owner indemnifies carrier for claims arising from building's negligence or building defects

Mutual waiver of subrogation: Each party's insurer waives subrogation rights against other party

Removal on Termination

Upon termination:

  • Carrier must remove all equipment, cables, and fixtures within 30-90 days
  • Carrier must repair any damage from removal
  • Carrier must restore premises to original condition
  • If carrier fails to remove, building owner can remove at carrier's expense

Abandoned equipment: If carrier abandons equipment, building owner can dispose of it and charge carrier for removal costs

Co-Location with Other Carriers

Non-exclusive: License is non-exclusive; building owner can license to multiple carriers

Shared facilities:

  • Multiple carriers share equipment room, risers, conduits
  • Each carrier has dedicated equipment space within room
  • Shared cable management (organized to avoid interference)
  • Coordination required if carriers' equipment conflicts

Competitive advantage: Multi-carrier building more attractive to tenants

Assignment and Sublicensing

Carrier's right to assign:

  • Carrier can assign to affiliates or successors with notice
  • Assignment to third parties requires building owner's consent (not to be unreasonably withheld)
  • Merger/acquisition of carrier = automatic assignment

No sublicensing: Carrier cannot sublicense to other carriers without building owner's consent

Building owner's concern: Wants to know and approve who has access to building

Building Owner Considerations

Goals:

  1. Attract tenants: Multiple carrier options, high-speed connectivity
  2. Maintain control: Non-exclusive revocable license, approval rights over installation
  3. Minimize liability: Carrier responsible for equipment, indemnifies owner
  4. Generate revenue: License fees (if market supports)
  5. Future flexibility: Right to relocate carrier if building redeveloped

Risks:

  • Carrier's equipment interferes with building systems
  • Installation disrupts tenants
  • Carrier abandons obsolete equipment
  • Safety issues (electrical, fire, structural)
  • Exclusive license prevents other carriers (CRTC violation)

Negotiation priorities:

  • Non-exclusive license (not lease)
  • Building owner designates equipment locations
  • Approval rights for installation plans
  • Adequate insurance and indemnification
  • Removal obligation on termination
  • Right to relocate if building redeveloped

Carrier Considerations

Goals:

  1. Serve building tenants: Access to customer base
  2. Long-term rights: Recoup equipment investment (typically 5-10 years)
  3. Operational flexibility: 24/7 access, upgrade equipment as technology evolves
  4. Minimize costs: Low or no license fees, shared facilities
  5. Avoid relocation: Expensive to move equipment

Risks:

  • Short term or terminable on short notice (can't recoup investment)
  • Building sold/redeveloped, new owner terminates license
  • Excessive license fees
  • Limited access (can't service equipment)
  • Forced relocation (high costs)

Negotiation priorities:

  • Long initial term (10+ years) or evergreen with long notice period
  • Reasonable license fee (flat fee, not revenue share)
  • 24/7 access for maintenance
  • Right to upgrade equipment
  • If relocated, building owner pays relocation costs and provides comparable space
  • Assignment rights for mergers/acquisitions

Drafting Best Practices

Clarity on license vs lease: "This is a license, not a lease. Licensee has no possessory interest in Licensed Premises. This License is revocable as provided herein."

Defined locations: Attach floor plans showing equipment room, riser routes, conduit paths, rooftop antenna location

Equipment specifications: Describe carrier's equipment (type, size, power requirements, heat load)

Coordination with tenants: Carrier's service agreements with tenants are separate from license. Building owner not party to carrier-tenant agreements.

Regulatory compliance: "This License is subject to CRTC regulations and applicable telecommunications laws."

Standard of care: Carrier must exercise "reasonable care" or "commercially reasonable efforts" in installation and maintenance


This skill activates when you:

  • Draft or review telecom license agreements
  • Negotiate with telecom carriers for building access
  • Advise building owners on multi-carrier strategy
  • Analyze CRTC compliance and reasonable access requirements
  • Structure license fees and revenue sharing
  • Address co-location and equipment room design
  • Handle carrier relocation due to building redevelopment
  • Resolve disputes over access rights or equipment interference